<?xml version="1.0" encoding="ISO-8859-1"?>
<metadatalist>
	<metadata ReferenceType="Journal Article">
		<site>mtc-m21d.sid.inpe.br 808</site>
		<holdercode>{isadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S}</holdercode>
		<identifier>8JMKD3MGP3W34T/4B95KLS</identifier>
		<repository>sid.inpe.br/mtc-m21d/2024/05.06.15.13</repository>
		<lastupdate>2024:05.06.15.13.19 urlib.net/www/2021/06.04.03.40 simone</lastupdate>
		<metadatarepository>sid.inpe.br/mtc-m21d/2024/05.06.15.13.19</metadatarepository>
		<metadatalastupdate>2024:05.18.21.32.56 sid.inpe.br/bibdigital@80/2006/04.07.15.50 administrator</metadatalastupdate>
		<doi>10.6008/CBPC2179-6858.2024.001.0001</doi>
		<issn>2179-6858</issn>
		<label>self-archiving-INPE-MCTIC-GOV-BR</label>
		<citationkey>PinheiroAlbBalDomAlm:2024:PhEvWa</citationkey>
		<title>Physical-chemical evaluation of the water quality of springs in the Floresta Manaós environmental protection area</title>
		<year>2024</year>
		<typeofwork>journal article</typeofwork>
		<secondarytype>PRE PI</secondarytype>
		<numberoffiles>1</numberoffiles>
		<size>1082 KiB</size>
		<author>Pinheiro, Liciane Assis,</author>
		<author>Albuquerque, Sâmia Dourado de,</author>
		<author>Baldan, Maurício Ribeiro,</author>
		<author>Domínguez, Lianet Aguilera,</author>
		<author>Almeida, Neila Braga de,</author>
		<resumeid></resumeid>
		<resumeid></resumeid>
		<resumeid>8JMKD3MGP5W/3C9JHTA</resumeid>
		<orcid></orcid>
		<orcid></orcid>
		<orcid></orcid>
		<orcid>0000-0002-6836-1916</orcid>
		<orcid>0000-0002-3935-4936</orcid>
		<group></group>
		<group></group>
		<group>COPDT-CGIP-INPE-MCTI-GOV-BR</group>
		<affiliation>Universidade Federal do Amazonas (UFAM)</affiliation>
		<affiliation>Universidade Federal do Amazonas (UFAM)</affiliation>
		<affiliation>Instituto Nacional de Pesquisas Espaciais (INPE)</affiliation>
		<affiliation>Universidade Federal do Amazonas (UFAM)</affiliation>
		<affiliation>Universidade Federal do Amazonas (UFAM)</affiliation>
		<electronicmailaddress>l.a.pinheiro@gmail.com</electronicmailaddress>
		<electronicmailaddress>samia.albuquerque@gmail.com</electronicmailaddress>
		<electronicmailaddress>mauricio.baldan@gmail.com</electronicmailaddress>
		<electronicmailaddress>lianetaguilera@gmail.com</electronicmailaddress>
		<electronicmailaddress>neilabraga@ufam.edu.br</electronicmailaddress>
		<journal>Revista Ibero-Americana de Ciências Ambientais</journal>
		<volume>15</volume>
		<number>1</number>
		<secondarymark>B2_INTERDISCIPLINAR B3_GEOGRAFIA B3_ADMINISTRAÇÃO,_CIÊNCIAS_CONTÁBEIS_E_TURISMO B4_ENGENHARIAS_III B5_ENSINO B5_ENGENHARIAS_I B5_CIÊNCIAS_AMBIENTAIS B5_CIÊNCIAS_AGRÁRIAS_I B5_BIODIVERSIDADE</secondarymark>
		<transferableflag>1</transferableflag>
		<contenttype>External Contribution</contenttype>
		<versiontype>publisher</versiontype>
		<keywords>Environmental Protection Area, Springs, Physical-Chemical Analysis, Water Quality Index, Área de Proteção Ambiental, Nascentes, Análises Físico-Químicas, Índice de Qualidade da Água.</keywords>
		<abstract>In this, we studied the physical-chemical parameters and socio-environmental conditions of water of two springs in the Floresta Manaós environmental protection area, located in Manaus, Brazil. The results of the analyses of the macroscopic environmental impacts show little or no interference due to anthropic actions in the first of the springs studied (S1), while, in the second spring (S2), the degree of preservation according to the studied parameters, was E (very bad). Physical-chemical parameters, such as electrical conductivity of water and pH showed unfavorable. The study of potentially toxic metals in the springs revealed that the iron in S2 is above the permitted limit, which may be the cause of the high conductivity values observed. RESUMO: Neste, estudamos os parâmetros físico-químicos e as condições socioambientais da água de duas nascentes da área de proteção ambiental Floresta Manaós, localizada em Manaus, Brasil. Os resultados das análises dos impactos ambientais macroscópicos mostram pouca ou nenhuma interferência devido às ações antrópicas na primeira das nascentes estudadas (S1), enquanto, na segunda nascente (S2), o grau de preservação de acordo com os parâmetros estudados, era E (muito ruim). Parâmetros físico-químicos, como condutividade elétrica da água e pH apresentaram-se desfavoráveis. O estudo dos metais potencialmente tóxicos nas nascentes revelou que o ferro no S2 está acima do limite permitido, o que pode ser a causa dos elevados valores de condutividade observados.</abstract>
		<area>FISMAT</area>
		<language>en</language>
		<targetfile>a+ARTIGO+8428+-+2024-04-27.pdf</targetfile>
		<usergroup>simone</usergroup>
		<readergroup>administrator</readergroup>
		<readergroup>simone</readergroup>
		<visibility>shown</visibility>
		<readpermission>deny from all and allow from 150.163</readpermission>
		<documentstage>not transferred</documentstage>
		<mirrorrepository>urlib.net/www/2021/06.04.03.40.25</mirrorrepository>
		<nexthigherunit>8JMKD3MGPCW/46KUES5</nexthigherunit>
		<dissemination>PORTALCAPES</dissemination>
		<hostcollection>urlib.net/www/2021/06.04.03.40</hostcollection>
		<username>simone</username>
		<agreement>agreement.html .htaccess .htaccess2</agreement>
		<lasthostcollection>urlib.net/www/2021/06.04.03.40</lasthostcollection>
		<url>http://mtc-m21d.sid.inpe.br/rep-/sid.inpe.br/mtc-m21d/2024/05.06.15.13</url>
	</metadata>
</metadatalist>